Properties | Measured results | Tests |
Specific weight | 1,55 - 1,74 g / cm3 at 20°C | Based on DIN ISO 1183 |
Young's modulus | 10.900 N/mm2 | Based on DIN 53457 |
Bending strength (12 mm panel) | 60 ± 5 N/mm2 | Based on DIN 53452 |
Compressive strength | 115 ± 10 N/mm2 | Based on EN ISO 604 |
Impact strength (12 mm panel) | 6,5 kJ/m2 | Based on DIN EN ISO 179 |
Impact resistance, falling 450g weight (12 mm panel) | No break at 100 ± 10 cm falling height | Based on ISO 19 712-2 |
Stability of gluing joints | 60 to 80 % material stability | Based on ISO 527 |
Barcol hardness | 65 ± 5 | Based on DIN EN 59 |
Erichsen scratch hardness, ground surface | 0,6 N | Based on DIN EN 438-2 |
Surface resistance | ROA = 3,3 x 1013Ω | Based on DIN 53482 |
Volume resistance | P = 3,1 x 1014 Ω ⋅ cm | Based on DIN 53482 |
Volume conductivity | σ = 3,2 x 10-15 Ω-1 ⋅ cm-1 | Based on DIN 53482 |
Tracking resistance | CTI 600 | Based on IEC 60112 |
Thermal conductivity at 20° C: λ-value | 1,3 W/m ⋅ K | Based on DIN 52612 |
Deformation resistance when heated 60' at constant 70°C (12 mm pannel) | No measurable change | Based on ANSI Z 124.3 (6.3) |
Length change under the influence of heat | 5,05 x 10-5 K-1 | Based on ASTM D 696 |
Stability in boiling water | No visible change | Based on DIN 53799 |
Stability in dry heat | No visible change up to 200°C | Based on DIN 68861 T7 |
Resistance against wet/dry change | No visible change | DIN EN 263 |
Resistance to glowing cigarette | No change after removal of tar residues | Based on DIN 53799 |
Flame retardancy | Meets B1 for 12 mm pannel B-s1, d0 | DIN 4102, pt. 1 EN 13501-1 + A1:2013 |
Fire test German Railway (DB) | S4 / SR2 / ST2 | DIN 54837 |
Fire rail vehicle | R1 - HL2 | EN 45545-2 2013 |
Migration test | Approved for food contact | IANESCO EU Regulation No. 10/2011 |
Compatibility with food | Physiologically suitable, approved for food contact | LGA/§31 LMBG |
Processing dust, toxicological behaviour | Not detrimental to health if max. allowable workplace concentration is observed | Certified by Dept. of Labor, Social and Environmental Medicine, Jena University |
Antibacterial efficacy | Well effective | ISO 22196 |
Lightfastness | Blue-lamp standard > 6 | ISO 4892-2 procedure A without irrigation |
Surface test (formation of cavities) | Requirements met | ANSI Z 124.3 (3.4) |
Black body | Δ E 0,8 | ANSI Z 124.3 (5.1) |
Stain resistance | Requirements met | ANSI Z 124.3 (5.2) |
Chemical resistance | Requirements met | ANSI Z 124.3 (5.5) |
Water resistance | Requirements met | ANSI Z 124.3 (6.0) |
Slip resistance | B | DIN 51097 |
Calorific value | 13,3802 Mj/kg | DIN 51900 |
Waste disposal | German waste key 17 02 03 | Plastic scraps |
Moulded pieces: | | |
Flammability test | Requirements met | ANSI Z 124.3 (5.6) |
Cold-hot water cycling test: 15° C - 90° C | CE conform (> 5000 cycles) | Based on DIN EN 13310 |
Sanitary Basins 15° C - 70° C | CE conform (> 5000 cycles) | Based on DIN EN 14688 |
CE-mark | Requirements met | DIN EN 14688 DIN EN 13310 |